Nexans: INSTRUMENTATION, CONTROL and COMMUNICATION CABLES

January 10, 2019

STANDARDS

International :  IEC 60331-1 or 2; IEC 60092-350; IEC 60092-360; IEC 60092-376; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

 

DESCRIPTION

APPLICATION: TCX 150/250 V armoured individually screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) cables are also selected where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

DESIGN

  1. Conductor:
    Stranded bare copper 
    Class 2
     
  2. Insulation:
    XLPE (cross-linked polyethylene)
     
  3. Individual screen:
    Alu/polyester tape with a tinned copper drain wire
     
  4. Inner Covering:
    Lapped polyester tape
     
  5. Armouring:
    Bare copper braid
     
  6. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour : grey 
     

MARKING

I NEXANS I TCX (I) “n” P or T “s” mm2 150/250V  90° C IEC 60092-376

IEC 60332-3-22 Cat. A “CE” ww/yy + metric marking

CORE IDENTIFICATION

Pair: white / blue with printed pair number

Triple: white / blue / red with printed triple number

Related Articles



Editor’s Pick: Featured Article

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s scalable engineering software, u-control 2000, adapts individually to your requirements. And, the u-control is powerful, compact and fully compatible with Weidmüller’s I/O system u-remote. This article looks at what makes u-control the heart of your automation.

Programmable logic controllers (PLCs) are one of the main components of any automated system. A typical control system has inputs, outputs, controllers (i.e., PLCs), and some type of human interaction with the system, a human machine interface (HMI), for example.

Read More



Latest Articles

  • NVIDIA 800 VDC Architecture Will Power the Next Generation of AI Factories

    November 4, 2025 By Mathias Blake, Martin Hsu, Ivan Goldwasser, Harry Petty and Jared Huntington The exponential growth of AI workloads is increasing data centre power demands. Traditional 54 V in-rack power distribution, designed for kilowatt (KW)-scale racks, isn’t designed to support the megawatt (MW)-scale racks coming soon to modern AI factories.  NVIDIA is leading the transition to 800 VDC data… Read More…

  • Efficient Power Monitoring at the Edge: Moxa’s DCI Solutions for Data Centres

    November 4, 2025 As data centres grow in higher densities to support AI-enabled workloads and more complicated operations, keeping the Power Usage Effectiveness (PUE) at optimum is critical at this time. Downtime is never acceptable. Also, without being able to see electrical systems in real-time, such as substations, UPS, switchgear, and HVAC, failures will take… Read More…